The Central Pollution Control Board has explained why air quality readings from several Delhi monitoring stations went blank during Diwali, saying the gaps were caused by an outdated validation system designed in 2015 that simply discards pollution data once it crosses a fixed limit.
In an 11-point clarification issued on its official X handle on Tuesday, the board said the data exists but is not used in calculating the official Air Quality Index, and it confirmed that a review of the methodology is now under way.
The clarification came after days of public concern over missing readings at monitoring stations across the national capital during and after Diwali, when particulate matter concentrations surged to extraordinary levels.
The Delhi Pollution Control Committee had released readings showing that PM2.5 concentrations at some locations had exceeded 1,000 micrograms per cubic metre on Diwali night, with Jahangirpuri recording up to 4,985 micrograms per cubic metre in real-time hourly measurements and Mundka reaching 3,744 micrograms per cubic metre. Several other stations recorded concentrations above 2,000 micrograms per cubic metre.
Reports said 45 of Delhi's 59 monitoring stations recorded missing hourly readings for at least one pollutant.
The board said the National Air Quality Index was introduced in 2015 and was designed for concentrations in the range of zero to 1,000 micrograms per cubic metre. The particulate matter analysers deployed at the time were calibrated for that measurement range, and the automated data validation system built into the network treats hourly readings beyond the calibrated range as outside range. Such readings are not used in the computation of the index.
The board put it plainly: the data is not missing, it is available, but it is not used in the calculation.
During extreme pollution episodes, which the board described as occasional events such as Diwali firecracker bursting, this design can appear as a data gap at the particular station concerned. The affected hours do not contribute to the 24-hour average of the relevant pollutant for that station.
That means the official daily average for a station can be calculated without the very hours when pollution was at its worst, a feature that has drawn sharp criticism from experts who say it understates the true scale of exposure on the most polluted nights of the year.
The board also defended the upper limit of 500 on India's air quality scale, saying the cap was a deliberate design feature of the 2015 methodology and was consistent with prevailing international practices, including the scale used by the United States Environmental Protection Agency. The National Air Quality Index operates on a scale of zero to 500, with six categories ranging from Good to Severe.
The board said that beyond this level the index remains in the Severe category and that extrapolating the index would not alter the assigned health impact category. An air quality reading of 500 or above indicated almost the same health risk and remained within the Severe category, it said.
The explanation has not settled the debate. Sources in the Environment Ministry have acknowledged that the 2015 data validation framework is outdated and needs revision. According to those sources, monitoring instruments have been upgraded over the years, but the methodology used to validate the data has remained unchanged.
The instruments have changed, the sources said, but the methodology has not changed. The board itself said internal deliberations and consultations are under way on how to process data beyond the system's designed measurement range, and that it is reviewing the existing methodology in light of technological progress and international standards.
According to one source familiar with the discussions, internal work has already begun, with two or three scientists working on the question, but no external expert committee has officially been constituted so far. The source said an expert group should be formed to examine the issue, as was done when the index was first developed in 2015. For now, the review remains an internal exercise, and no timeline has been announced for when a revised methodology might be put in place.
The board also addressed the differences between official readings and the figures shown by private air quality applications, which often display far higher numbers during pollution spikes. It said many private platforms use data from government and non-government sources, including low-cost sensors with varying calibration and data quality standards.
Private applications may show higher values during brief pollution spikes and lower values when concentrations fall, whereas the National Air Quality Index reflects exposure averaged over the previous 24 hours. The difference in values, the board said, is attributable to differences in the measurement of pollutant concentration and in methodology, and not to under-reporting.
The board pointed to the scale of the monitoring network it now operates. The number of continuous ambient air quality monitoring stations across the country has increased from 30 in 2014-15 to 634 at present, with Delhi's monitoring sites rising from 10 to 59 over the same period.
The expansion means far more of the city is covered than a decade ago, but the clarification makes clear that the growth in the number of stations has not been matched by an update to the rules governing what the stations' data is allowed to count.
The timing of the clarification matters because Delhi's air remains poor even after the Diwali peak. The city's 24-hour average air quality index eased to 299, in the Poor category, in the pollution control board's 4 pm bulletin on Tuesday, down from 344 a day earlier, but it rose again to 302 by 6 pm. The worst stations in the evening bulletin were IIT Delhi at 389, Pusa at 381 and Chandni Chowk at 380.
Stage III restrictions under the Graded Response Action Plan remain in force across Delhi and the National Capital Region, and the Supreme Court has separately flagged vehicular emissions as a growing contributor to the capital's air, alongside the seasonal surge from firecrackers and stubble burning.
For residents, the practical consequence of the board's explanation is stark. On the night when Delhi's air was at its most dangerous, the official system was designed to stop counting. The readings that would have shown the true peak were recorded by the instruments, but the validation rules set them aside, and the hours they covered were left out of the daily averages that shape public understanding and policy response.
The board insists the data exists and that nothing was hidden. The question now is whether the review it has promised will change a system that was built for a different era of pollution, when concentrations above 1,000 micrograms per cubic metre were treated as beyond the range of measurement rather than as a recurring reality of Diwali night in Delhi.
Until the methodology is revised, the gaps are likely to return with every extreme episode. The board has said the review is under way and that consultations are continuing. What it has not said is when the system will be able to count the pollution it already measures, or when the official index will reflect the full severity of the air that Delhi breathes on its worst nights.
(Reporting based on Business Standard, Outlook India and Asianet News.)